DURAMAX Diesel Engine (LML/LGH) - 2011
Driving and Operating 9-49
Programmable
Parameters
Factory Setting Minimum Value Maximum Value
Engine Shutdown warning DISABLED DISABLED ENABLED
Set Low Fuel level for
Engine Shutdown
15% 0 25%
Engine Run Time While
PTO is Active – Timer
7 Hours 4 minutes 7 hours
Min. PTO Engage Speed 500 RPM 500 RPM 1800 RPM
Max. PTO Engine Speed 1800 RPM 950 RPM 3100 RPM
PTO Standby RPM 850 RPM
500 RPM Normal engine
idle will override if higher
than Standby Speed
3100 RPM
PTO Set Speed 1 1250 RPM
500 RPM PTO Set Speed 1
cannot be set below PTO
Standby speed
3100 RPM
PTO Set Speed 2 1700 RPM
500 RPM PTO Set Speed 2
cannot be set below PTO
Standby speed
3100 RPM
Maximum Operating Speed 2100 RPM 500 RPM 3100 RPM
Tap Step 100 RPM 4 RPM 500 RPM
Ramp Rate 200 RPM 4 RPM 1000 RPM