7. The ignition must be turned to LOCK or
ACCESSORY prior to attaching the cables to the
battery, or serious damage to the Vehicle Control
Module (VCM) may result.
The windshield wiper switch and the radio must be
turned off before attaching cables to the battery.
8. Disconnect the positive (+) battery cable at the
underhood power distribution center. Remove
the nut from the 8 mm stud (see illustration).
9. Install the 40 amp MegaFuse (from Step 4) in the
front holder on the underhood power distribution
center over the stud. Reinstall the positive (+)
battery cable with the mounting screw through the
MegaFuse terminal. Replace the 8 mm nut on
the stud. Torque both the nut and screw to
1.3-2.7 lb.-ft (6-12 Y).
10. Reconnect the negative () battery cable to the
battery. Torque the bolt to 12.5 lb-ft. (17 Y).
11. Reset the clock time and radio pushbuttons as
desired.
The IGN A and IGN B connections have voltage
supplied and are hot when the ignition is turned to
ACCESSORY or RUN (pink color wire).
The BAT A and BAT B connections have voltage
supplied and are hot at all times (orange color wire).
The combined electrical load of IGN A and BAT A
must not exceed 21 amps (250 watts). Additionally, the
combined electrical load of IGN B and BAT B must not
exceed 21 amps (250 watts). The combined electrical
load of all circuits must not exceed 28 amps (340 watts).
Underhood Power Distribution Center