The variable PTO mode controls
engine speed, and PTO load
engagement is selected by either
the PTO in-cab or remote switches.
Engine speed selection is variable
between base engine idle speed
and a maximum of 3100 rpm
(factory setting 2100 rpm).
In the mobile PTO mode, the
vehicle will operate at a vehicle
speed resulting from the current
PTO engine speed request and
current transmission gear range
selected.
Vehicle speed stability is greatly
improved by operating the
transmission in manual mode
because upshifts are limited. Mobile
PTO is only available in M1, M2,
and M3. This reduces the maximum
vehicle speed while allowing high
engine speed operation.
PTO Switch Operation
To engage PTO, press and release
the in-cab PTO switch or, press and
release the remote PTO arm switch,
then within five seconds, press and
release the PTO remote start/
shutdown switch. The vehicle will
increase engine speed to a factory
preset engine speed (900 rpm). This
PTO stand-by speed is not intended
to be an operational PTO speed, but
allows the engagement of the PTO
at lower initial start-up rpm to match
with the engagement of the PTO
load relay.
The initial stand-by speed can be
adjusted by holding the accelerator
to the desired engine speed, then
pressing and releasing the in-cab
PTO switch. The current engine
speed will become the new stand-by
speed. This adjustment can only be
done once at the initial engagement
of PTO. The initial stand-by speed
adjustment must be between engine
base idle speed and 1500 rpm
(maximum PTO engage speed).
Press and release the in-cab switch.
The engine speed will be reduced to
the base idle speed and the PTO
load relay will be disengaged. In
remote mode, press and release the
PTO remote start/shutdown switch.
PTO Operational Speed Control
SET: Press and hold the
accelerator to obtain the desired
engine speed, then press and
release the SET switch. The
current engine speed will be
maintained. This action can be
repeated as desired to a higher rpm
value. The PTO set speed cannot
exceed 3100 rpm.
TAP-DOWN: Press and release the
SET switch to reduce the engine
speed by increments of 100 rpm.
This increment can be adjusted by a
service technician.
COAST: Press and hold the SET
switch to reduce the rpm by 150 rpm
per second until the desired engine
speed is reached or until the initial
PTO standby speed is reached.
Seitenansicht 73