Chevrolet Silverado HD Wartungshandbuch Seite 79

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 123
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 78
Black plate (52,1)
Chevrolet/GMC Duramax Diesel Supplement (GMNA Localizing-U.S./Canada-
7132827) - 2015 - CRC - 10/21/14
9-52 Driving and Operating
Programmable
Parameters
Factory Setting Minimum Value Maximum Value
Maximum Remote
Potentiomete Threshold
95% 50% 100%
Remote Set Switch
Transition to Low
Voltage (<1.66 V)
SET SPEED 1 STANDBY SPEED, SET SPEED 1, or SET SPEED 2
Remote Set Switch
Transition to Open State
(>1.66 V, <3.33 V)
PTO STANDBY STANDBY SPEED, SET SPEED 1, or SET SPEED 2
Remote Set Switch
Transition to High
Voltage (>3.33 V)
SET SPEED 2 STANDBY SPEED, SET SPEED 1, or SET SPEED 2
If the PTO factory preset
parameters do not match the
settings described above, then they
may have already been altered in
order to satisfy the requirements of
the installed PTO system and body
equipment.
See www.gmupfitter.com for more
information on the installation of
wiring and programming for PTO
aftermarket equipment.